KMC Smart Tap Outlet With Energy Meter
KMC Smart Tap Outlet With Energy Meter
Device Type: plugElectrical Standard: usBoard: esp8266
  
      
  
        
GPIO Pinout
| Pin | Function | 
|---|---|
| GPIO16 | Push Button | 
| GPIO1 | Blue LED (Inverted: true) | 
| GPIO15 | Outlet 1 | 
| GPIO13 | Outlet 2 | 
| GPIO14 | Outlet 3 | 
| GPIO12 | HLW8012 SEL Pin | 
| GPIO04 | HLW8012 CF Pin | 
| GPIO05 | HLW8012 CF1 Pin | 
Basic Config
esphome:  name: KMC-Smart-Tap  friendly_name: KMC-Smart-Tap
esp8266:  board: esp01_1m  restore_from_flash: True
# Enable logginglogger:
# Enable Home Assistant APIapi:  encryption:    key: !secret api_key
ota:  password: !secret ota_password
wifi:  ssid: !secret wifi_ssid  password: !secret wifi_password
  # Enable fallback hotspot (captive portal) in case wifi connection fails  ap:    ssid: !secret fallback_wifi_ssid    password: !secret fallback_wifi_password
captive_portal:
sensor:  - platform: hlw8012    sel_pin: GPIO12    cf_pin: GPIO4    cf1_pin: GPIO5    update_interval: 30s    current:      name: "KMC01 Current"    voltage:      name: "KMC01 Voltage"      filters:        # Map from sensor -> measured value        - calibrate_linear:            - 0.0 -> 0.0            - 135.0 -> 122.0    power:      name: "KMC01 Power"
  - platform: wifi_signal    name: "KMC01 WiFi signal"    update_interval: 60s
  - platform: uptime    name: "KMC01 Uptime"
text_sensor:  - platform: version    name: "KMC01 ESPHome Version"
button:  - platform: restart    name: "KMC01 Restart" # optional device restart switch
switch:  - platform: gpio    name: "KMC01 Outlet 3"    pin: GPIO14    id: outlet_3    restore_mode: RESTORE_DEFAULT_ON  - platform: gpio    name: "KMC01 Outlet 2"    pin: GPIO13    id: outlet_2    restore_mode: RESTORE_DEFAULT_ON  - platform: gpio    name: "KMC01 Outlet 1"    pin: GPIO15    id: outlet_1    restore_mode: RESTORE_DEFAULT_ON
binary_sensor:  - platform: gpio    pin:      number: GPIO16      mode: INPUT      inverted: True # Normally off /Press on    name: "KMC01 button"    on_multi_click: # Button Behavior (Click Outlets On/Off)    - timing:        - ON for at most 1s        - OFF for at most 1s        - ON for at most 1s        - OFF for at most 1s        - ON for at least 1s        - OFF for at least 0.2s      then:        # Triple Click Toggle Outlet 3 On/Off        # (Two presses followed by a long press)        - logger.log: "Triple Click"        - switch.toggle: outlet_3    - timing:        - ON for at most 1s        - OFF for at most 1s        - ON for at least 1s        - OFF for at least 0.2s      then:        # Double Click Toggle Outlet 2 On/Off        # (One press followed by a long press)        - logger.log: "Double Click"        - switch.toggle: outlet_2    - timing:        - ON for at least 1s        - OFF for at least 0.2s      then:        # Single Click Toggle Outlet 1 On/Off        # (One long press)        - logger.log: "Single Click"        - switch.toggle: outlet_1  - platform: status    name: "KMC01 Status"
status_led:  pin:    number: GPIO1    inverted: yes # yes for off/no for on